Chlorine, Ozone, Chlorine dioxide

Stage – Pre-disinfection, Filtration, Disinfection, Storage & Distribution

Two different technologies (amperometry, photometry) and three types of instruments are available for monitoring free chlorine, ozone, chlorine dioxide or monochloramine. The choice depends on water treatment methods:

Amperometric three electrode system TRIDES: Treatment with free chlorine, chlorine dioxide or ozone. Dual channel system (chlorine and pH) will provide on-line conversion from hypochlorous acid to free chlorine without reagents.

Process photometers CODES: Work under the same conditions as the amperometric system. In addition, they can be used for monochloramine. pH compensation is not necessary because the reagents contain a buffer solution.

Amperometric systems have lower cost of ownership (no reagents). Under unknown conditions (and at pH above 8.5) Swan recommends using a photometer.

CHEMATEST portable photometer: A high precision portable photometer is needed for verification and calibration in any case.

Chematest 42

Portable universal measuring device instrument for photometric determinations analysis, sensor-based measurements and 90 ° IR turbidity measurement.

Details >

IXA70065042_Chematest42_ohneReagenzien

Monitor AMI Trides

Amperometric analyzer for disinfectans such as hypochlorous acid, free chlorine, chlorine dioxide, ozone, bromine, iodine.

Details >

IXA261110XX_AMI_Trides

Monitor AMI Trides compact version AC

Amperometric analyzer for disinfectans such as hypochlorous acid, free chlorine, chlorine dioxide, ozone, bromine, iodine. Compact version mounted on panel 300 x 530 x 200 mm

Details >

IXA26111100_AMI_Trides_comp_Low.jpg

Analyzer AMI Codes-II AC

Colorimetric process analyzer (DPD-method) for measurement and dosing control of disinfectants such as free chlorine, hypochlorous acid, chlorine dioxide, ozone, bromine, iodine and monochloramine.

Details >

IXA2544X1000 AMI_Codes-II

Analyzer AMI Codes-II TC AC

Colorimetric process analyzer (DPD-method) for measurement of total chlorine and calculation of dichloramine.

Extended measurement range up to 10 ppm.

Details >

IXA2544X6000 AMI Codes-II_TC.jpg

Analyzer AMI Codes-II CC AC

Colorimetric process analyzer (DPD-method) for measurement of free chlorine, monochloramine, combined chlorine and total chlorine.

Details >

IXA2544X7000 AMI_Codes-II_CC

Analyzer AMI Codes-II O3 AC

On-line monitoring of ozone in pharmaceutical water storage and distribution systems. Ideal for proving the complete destruction of ozone before water use due to a low detection limit of 1 ppb and no sensitivity loss in absence of ozone.

Details >

IXA254413000-AMI-Codes_II-O3.jpg

Chematest 30

The flexible and robust solution for the determination of disinfectants, pH value and cyanuric acid.

Details >

IXA70065030 Chematest 30_ohneReagenzien.png

Chematest 35

Portable universal measuring instrument for photometric determinations and sensor-based measurements supplied in a carrying case with accessories.

Details >

Chematest35_inkl.Koffer.jpg