Chlorine, Ozone, Chlorine dioxide

Stage – Pre-disinfection, Filtration, Disinfection, Storage & Distribution

Two different technologies (amperometry, photometry) and three types of instruments are available for monitoring free chlorine, ozone, chlorine dioxide or monochloramine. The choice depends on water treatment methods:

Amperometric three electrode system TRIDES: Treatment with free chlorine, chlorine dioxide or ozone. Dual channel system (chlorine and pH) will provide on-line conversion from hypochlorous acid to free chlorine without reagents.

Process photometers CODES: Work under the same conditions as the amperometric system. In addition, they can be used for monochloramine. pH compensation is not necessary because the reagents contain a buffer solution.

Amperometric systems have lower cost of ownership (no reagents). Under unknown conditions (and at pH above 8.5) Swan recommends using a photometer.

CHEMATEST portable photometer: A high precision portable photometer is needed for verification and calibration in any case.

Monitor AMI Trides

Amperometric analyzer for disinfectans such as hypochlorous acid, free chlorine, chlorine dioxide, ozone, bromine, iodine.

Details >

IXA261110XX_AMI_Trides

Monitor AMI Trides compact version AC

Amperometric analyzer for disinfectans such as hypochlorous acid, free chlorine, chlorine dioxide, ozone, bromine, iodine. Compact version mounted on panel 300 x 530 x 200 mm

Details >

IXA26111100_AMI_Trides_comp_Low.jpg

Analyzer AMI Codes-II AC

Colorimetric process analyzer (DPD-method) for measurement and dosing control of disinfectants such as free chlorine, hypochlorous acid, chlorine dioxide, ozone, bromine, iodine and monochloramine.

Details >

IXA2544X1000 AMI_Codes-II

Analyzer AMI Codes-II TC AC

Colorimetric process analyzer (DPD-method) for measurement of total chlorine and calculation of dichloramine.

Extended measurement range up to 10 ppm.

Details >

IXA2544X6000 AMI Codes-II_TC.jpg

Analyzer AMI Codes-II CC AC

Colorimetric process analyzer (DPD-method) for measurement of free chlorine, monochloramine, combined chlorine and total chlorine.

Details >

IXA2544X7000 AMI_Codes-II_CC

Analyzer AMI Codes-II O3 AC

On-line monitoring of ozone in pharmaceutical water storage and distribution systems. Ideal for proving the complete destruction of ozone before water use due to a low detection limit of 1 ppb and no sensitivity loss in absence of ozone.

Details >

IXA254413000-AMI-Codes_II-O3.jpg

Chematest 30

The flexible and robust solution for the determination of disinfectants, pH value and cyanuric acid.

Details >

Chematest 30 ink, Koffer.jpg

Chematest 35

Portable universal measuring instrument for photometric determinations and sensor-based measurements supplied in a carrying case with accessories.

Details >

Chematest35_inkl.Koffer.jpg